Products


Motor Protection Devices

VOLTAGE SCANNER

PROTECTION PROVIDED

LOW Voltage Tripping
HIGH Voltage Tripping
Phase Unbalance protection
Protection against SINGLE PHASING.
Protection against REVERSE PHASING.
Time Delay
Salient Features : 
• Very High Accuracy
• Wide Range of Supply Variation

• Protection against Under Voltage
• Protection against Over Voltage.
• Indication for High Voltage, Low Voltage   Single Phasing & Reverse Phasing along   with Healthy indication.


• Single Phasing Protection.
• Protection for Reverse Phasing
• Phase Unbalance Protection.
• Indication unaffected by meter    mounting position.
• No separate auxiliary supply    required.
• Latest Technology
 
Single Phase Preventor :

< SPP-1

Salient Features : 

• Operates on the principle of sensing negative sequence components of the system.
• Suitable for the protections of motors of any H.P.
• Protection against SINGLE PHASING.
• Protection against REVERSE PHASING.
• Individual trip indication for single phasing reverse phasing and indication for output relay ON.

• No separate auxiliary supply required.

< LVM

Salient Features : 

• Operates on the principle of sensing negative sequence components of the system.
• Suitable for the protections of motors of any H.P.
• Protection against SINGLE PHASING.
• Protection against REVERSE PHASING.
• Protection against UNBALANCE in supply.
• Variable trip voltage setting for undertake / over voltage protection. Fixed unbalance trip setting at 40 volts.
• Individual trip indication for under voltage, over voltage, single phasing reverse phasing and indication for output relay ON.

• No separate auxiliary supply required.


VOLTAGE MONITORING RELAY

< Salient Features : 

• Separate ON & OFF delay selectable by switch.
• Suitable for the protections of motors of any H.P.
• Indication for Timer
• Protection against SINGLE PHASING supply.
• Protection against REVERSE PHASING supply.
• Automatic Tripping for UNBALANCE in supply.
• Automatic Tripping for under / over voltage with variable range setting
• Individual trip indication for under voltage, over voltage, single phasing reverse phasing.
• Indication for Timer.
• No separate auxiliary supply required.


AC Timer

 

Compressor Guard 

<  Salient Features : 

• Having taken care of both voltage and current.
• Compressor guard 1 A/C controls 1 A/C while 2 A/C model controls 2 A/C's
• Protections against overload (Electronic Current sensing type), Under   Voltage and Over Voltage.
• Continuously adjustable overload setting to suit different capacities of    compressor.
• Manual Reset by means of Power ON / OFF switch for overload tripping   and auto.
• Reset for under / over voltage tripping.
• In single A/C model power on delay timer of fixed time delay as per   customers specifications to provide sufficient time to equalise the   pressure. Timer comes into operation every time the compressor goes   OFF, either due to power failure or due to safety protection operated in   this unit. Adjustable time delay by means of DTP switches in four steps of   seconds / minutes ( optional features on extra cost.)
• In 2 A/C model, power -on delay timer of 2min. 15 sec. to provide   sufficient time to equalise the pressure.
• After every 6 hours the changeover takes place i.e. the running A/C is switched off and the other A/C is    switched on. there is a time delay of 1 min. between the switching over of A/C'. The changeover also take    place if any A/C is faulty (overload). the running A/C tripped and the overload indication glows. After a time    delay of 1 min. the A/C is switched on and the overload then the system can be resettled.
• Battery back-up provided to keep the elapsed running time of one A/C in memory so that whenever power is    restored, that particular A/C will run for remaining pre-selected time only and after that the change over will    take place.
• Trip time delay of 8 sec. for under / over voltage. Trip time delay of 8 sec. for initial overload and 5 sec. for    subsequent overload tripping.
• Separate output for blower fan motor for instant operation.
• Power to this unit is made ON-OFF by means of ON/OFF switch.
• To be directly connected to load no need of extra starter
• Indications for Power On, Timer On, U/V Trip, O/C Trip, AC ON
• Being Electronic, Excellent repeatability and high degree of reliability unaffected by changes in ambient   temperature. 